+86-18602148684 wanglu@lianhuakeji.com

Facebook
Twitter
Youtube
LinkedIn
Pinterest

Shanghai Lianhua Industrial Co., Ltd.
  • Home
  • Products
    • Water quality analyzer
      • COD analyzer
      • BOD meter
      • Multi-parameter water quality instruments
      • Turbidity meter
      • TSS meter
      • Residual chlorine meter
      • Ammonia nitrogen analyzer
      • Total phosphorus analyzer
      • Total chlorine analyzer
      • total nitrogen analyzer
    • Test Kit & Fast Test paper
    • Laboratory digester
    • Reagents
    • pH/DO/Conductivity/ORP/Ion Meter
      • PH meter
      • Dissolved oxygen meter
      • Conductivity/TDS meter
    • Titrator
    • Centrifuge
    • Spectrophotometer
      • AAS Atomic absorption spectrophotometer
      • UV/VIS Spectrophotometer
      • Split Beam UV/VIS Spectrophotometer
      • Double Beam UV/VIS Spectrophotometer
    • Oil in water analyzer
    • Incubator
      • Muffle Furnace
      • Laboratory incubator
      • Drying oven
    • TOC
    • Vertical Autoclave
    • Water bath
    • Laboratory balance
      • Analytical balance
      • Electronic balance
  • About us
  • News
    • Company news
    • Industry-news
  • Certificate
  • F.A.Q
  • Feedback
  • Contact us
  1. Home
  2. Products
  3. Spectrophotometer
  4. AAS Atomic absorption spectrophotometer
  5. Laboratory Flame AAS atomic absorption s
  • Laboratory Flame AAS atomic absorption spectrophotometer 190-900nm

Laboratory Flame AAS atomic absorption spectrophotometer 190-900nm

AAS atomic absorption spectrophotometer 190-900nm
Inquiry Send Email

Description

Product Introduction

Atomic absorption Spectrophotometer is used to analyze metal elements based on the effect of the ground state atomic vapor of a substance on the absorption of characteristic radiation. It can sensitively and reliably determine trace or trace elements.


Features

1, Build-in computer data processing and LCD display: stable and reliable with the functions of integral holding, peakheight and area, auto zero adjusting, deuterium lamp background correction, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.

2, Stability: Double-beam system can automatically compensate the light source drift and wavelengthdrift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.

3, Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.

4, High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.

5, High energy optical path: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced.

6, Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.

7, Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.

8, Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame.

9, Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.


Specifications

● WL range 190-900nm
● WL accuracy ≤±0.5nm
● WL repeatability ≤0.3nm (single direction)
● Spectrum bandwidth 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
● Resolution <40%
● Base line stability ±0.004Abs/30min
● Characteristic concentration of copper ≤ 0.04μg/ml/1%
● Detection limit of copper ≤ 0.08μg/ml
● Background calibration ability Greater than 30 times
● RS232 including
● Printer Optional
● Power supply 220V 3A, 50Hz
● G.W. 138Kg / 56Kg
● Package size 1250mmx795mmx765mm (Main instrument)
545mmx445mmx1385mm ( Accessories )



Inquiry Us





Related Products

Aerobic Count Plate

Aerobic Count Plate

Ammonia Nitrogen Water Quality Analyzer 5B-6D

Ammonia Nitrogen Water Quality Analyzer 5B-6D

16 positions touch screen fast laboratory COD reactor LH-A116

16 positions touch screen fast laboratory COD reactor LH-A116

COD, ammonia nitrogen, total phosphorus, total nitrogen and turbidity Multi-parameter water quality analyzer 5B-6C(V11)

COD, ammonia nitrogen, total phosphorus, total nitrogen and turbidity Multi-parameter water quality analyzer 5B-6C(V11)

Biochemical oxygen demand meter/BOD meter LH-BOD306

Biochemical oxygen demand meter/BOD meter LH-BOD306

Portable water pH meter LH-220

Portable water pH meter LH-220

Product Categories

  • Water quality analyzer
    • COD analyzer
    • BOD meter
    • Multi-parameter water quality instruments
    • Turbidity meter
    • TSS meter
    • Residual chlorine meter
    • Ammonia nitrogen analyzer
    • Total phosphorus analyzer
    • Total chlorine analyzer
    • total nitrogen analyzer
  • Laboratory digester
  • Reagents
  • Test Kit & Fast Test paper
  • pH/DO/Conductivity/ORP/Ion Meter
    • PH meter
    • Dissolved oxygen meter
    • Conductivity/TDS meter
  • Spectrophotometer
    • AAS Atomic absorption spectrophotometer
    • UV/VIS Spectrophotometer
    • Split Beam UV/VIS Spectrophotometer
    • Double Beam UV/VIS Spectrophotometer
  • Titrator
  • Centrifuge
  • Oil in water analyzer
  • Incubator
    • Muffle Furnace
    • Laboratory incubator
    • Drying oven
  • TOC
  • Vertical Autoclave
  • Water bath
  • Laboratory balance
    • Analytical balance
    • Electronic balance

Links

AlibabaYoutubeChinese websiteGoogle.comBaidu.com

LatestPost

  • Top 10 Led Street Light Manufacturers in China
    Top 10 Led Street Light Manufacturers in
    2023-03-28
  • UV oil meter
    UV oil meter
    2024-04-17
  • Infrared oil content meter introduction
    Infrared oil content meter introduction
    2024-04-17

Feedback

Contact Us

2355960360

+86 18602148684

+86-18602148684

wanglu@lianhuakeji.com

elin1234520

Room 203, Building 61, Hongcao Garden, No.421 Hongcao Road, Xuhui District, Shanghai

MOBILE WEBSITE

Copyright © 2013-2019 Shanghai Lianhua Industrial Co., Ltd. All Rights Reserved.

  • Skype.
  • E-mail
  • Whatsapp
  • Inquiry